A dual-active-bridge converter joins a primary dc bus V₁=400 V to a secondary dc bus…

Problem

Power Electronics and Energy Systems practice problem

A dual-active-bridge converter joins a primary dc bus V1=400 VV_1=400\,\mathrm{V} to a secondary dc bus V2=200 VV_2=200\,\mathrm{V} through an ideal transformer of turns ratio n=Np/Ns=2n=N_p/N_s=2 and a series inductance L=50 μHL=50\,\mu\mathrm{H} referred to the primary. Both H-bridges switch at fs=100 kHzf_s=100\,\mathrm{kHz} with fifty-percent duty. The only control coordinate is the phase ϕ\phi (radians) by which the primary square wave leads the secondary square wave. The average power from primary to secondary isP(ϕ)=nV1V2ωL ϕ(1−∣ϕ∣π),∣ϕ∣≤π,P(\phi)=\frac{n V_1 V_2}{\omega L}\,\phi\Bigl(1-\frac{|\phi|}{\pi}\Bigr), \qquad |\phi|\le\pi,where ω=2πfs\omega=2\pi f_s. The rails are voltage-matched:
nV2=V1n V_2=V_1.

1. Evaluate the prefactor nV1V2/(ωL)n V_1 V_2/(\omega L) exactly. Substitute
ϕ=π/6\phi=\pi/6 and proveP(π/6)=2222.222 WP\bigl(\pi/6\bigr)=2222.222\,\mathrm{W}from primary to secondary.

2. On ∣ϕ∣≤π|\phi|\le\pi, prove that ∣P∣|P| is maximized at
∣ϕ∣=π/2|\phi|=\pi/2 withPmax⁡=4 kW.P_{\max}=4\,\mathrm{kW}.3. Solve P(ϕ)=3 kWP(\phi)=3\,\mathrm{kW} for ϕ∈(0,π)\phi\in(0,\pi). Prove that
the two roots are π/4\pi/4 and 3π/43\pi/4, and select ϕ=π/4\phi=\pi/4 as the operating point of lower circulating current.

4. Audit both sentences: (i) “negative ϕ\phi still sends
2222.222 W2222.222\,\mathrm{W} from primary to secondary”; (ii) “the 3 kW3\,\mathrm{kW} roots are interchangeable because circulating current depends only on power, not on ϕ\phi.”

Do not replace the phase-shift power law by a hard-switching conduction / transition / recovery loss ledger, and do not analyze transformer reset, flux walk, or core saturation.

Hint

Hint

Write ωL=2π⋅105⋅50×10−6=10π\omega L=2\pi\cdot 10^5\cdot 50\times 10^{-6}=10\pi. The numerator is nV1V2=160000n V_1 V_2=160000, so the prefactor is 16000/π16000/\pi.

Check your work

Work the problem yourself first. Then open it in Training to check your answer and read the full worked solution.

The answer check and full solution for this problem come with ProofAnvil Practice membership ($19 USD monthly). See membership. Or start with the free Power Electronics and Energy Systems sample problem: Try the free sample problem.