Control Systems · State-space, controllability, and observability
A rigid body in planar translation is actuated by two independent thrusters
Problem
Control Systems practice problemA rigid body in planar translation is actuated by two independent thrusters. With in seconds and state , where is position in metres, is velocity in metres per second, and is a thruster-filter state in metres per second, the model is withThe first column of is dimensionless in the sense of mapping onto ; the entry has units ; the second column of has units if the second input is taken in metres per second. Take both inputs in a consistent set of units so that the displayed numerical matrices apply as written. Let . The controllability matrix is the block .
(a) Compute and . Form and determine . Decide complete controllability.
(b) Apply the PBH test at each eigenvalue of (compute first). Confirm the conclusion of (a).
(c) Now disable the first thruster by replacing with its second column only. Recompute and the PBH ranks. Decide controllability of the single-input pair . Identify a one-dimensional subspace of states that cannot be reached from the origin using only .
Hint
Hint** Compute the two-input Kalman matrix first; then repeat with only the second column of , which feeds the last coordinate of the displayed chain.
Check your work
Work the problem yourself first. Then open it in Training to check your answer and read the full worked solution.
The answer check and full solution for this problem come with ProofAnvil Practice membership ($19 USD monthly). See membership. Or start with the free Control Systems sample problem: Try the free sample problem.
More Control Systems practice problems
- A single-loop unity-feedback architecture is defined as followsDynamic models, linearization, and feedback structure
- A linearised liquid-level plant occupies a tank of constant horizontal area A=1.25 m²Dynamic models, linearization, and feedback structure
- Time t is in seconds; the output y is a shaft angle in radians and the reference r is…Dynamic models, linearization, and feedback structure
- Time t is in seconds; angles are in radiansTime response and stability criteria
- Use the one-sided Laplace transform with rest initial conditions and s in s⁻¹Root-locus and frequency-response design
- Two lumped thermal masses exchange heat by conduction and lose heat to a constant ambientState-space, controllability, and observability
- Use the unilateral z-transformState feedback and observers
- Time t is in seconds and θ is in radiansDigital control and robustness foundations